housing dimensions 400 x 250 x 160 mm (W x H x D)
power supply 100 ... 240 Volt / 50 ... 60 Hz
operating voltage 15 V DC, about 20 watts
water hardness range raw water 0.70 mmol/l to 10.7 mmol/l
water hardness range soft water 0.0018 mmol/l to 0.18 mmol/l
threshold value range soft water 0.01 mmol/l to 0.18 mmol/l

Effectively prevent scale deposits

Softcontrol Data

Completely monitor the soft water for increased hardness levels. Softcontrol Data offers individual adjustment options and a clear display of information. For increased operational and process reliability with the best user-friendliness.

At a glance

  • no use of indicators
  • continuous measurement as long as water flows
  • self-monitoring of the device system
  • separate alarm for water hardness and service
  • measuring value output via display and via 4 to 20 mA current loop
  • data storage in electronic operations diary (flash drive)
  • easy installation and parameterization
  • ecological operation because there is no addition of indicators
  • networking to higher-level control centers via LAN interface with MODBUS/TCP

Ideal solution for

  • big laundries
  • brewery
  • bakery

Prevents

  • hardness breakthrough
  • scale deposits
  • lamination

Advantages

  • monitoring device for variable water hardness threshold values from 0.01 mmol/l to 0.18 mmol/l relative to the inlet water hardness
  • complete alarm system for upstream softening systems with high safety requirements for soft water quality to prevent scale deposits
  • automatic data storage and data output via current loop

Further products

OFS GmbH

Weichwasser einfach überwachen / simply monitor soft water

Softcontrol Smart

The simplest residual hardness monitoring based on 10 % of the raw water hardness

Small, compact and very uncomplicated

more: monitoring water hardness
kalkablagerung effektiv verhindern / Effectively prevent scale deposits

Softcontrol Data

Visualized residual hardness control by display

Individually and clearly arranged

more: monitoring water hardness
kalkablagerung effektiv verhindern / Effectively prevent scale deposits

Softcontrol Carbonat

Monitoring of decarbonization processes

Soft water threshold values from 0,1 mmol/l to 0,9 mmol/l

more: monitoring carbonate
kalkablagerung effektiv verhindern / Effectively prevent scale deposits

Softcontrol V-UE

Monitoring of blended water systems

For variable water hardness threshold values from 0.2 mmol/l to 10.8 mmol/l

more: analysis blended water