housing dimensions 400 x 250 x 160 mm (W x H x D)
power supply 100 … 240 V / 50 … 60 Hz
operating voltage 15 V DC, about 20 watts
water hardness range raw water 0.9 mmol/l ... 10.8 mmol/l
water hardness range soft water 0.0018 mmol/l ... 0.18 mmol/l
threshold value range soft water 0.01 mmol/l ... 0.18 mmol/l

Automatically trigger regeneration of the softener

Softcontrol RM

The economy of a water softener can be improved by control and optimized activation.
Thus, Softcontrol RM offers monitoring of the soft water for increased hardness concentrations as well as the external regeneration release of the softener for quality-controlled double water softening systems.

At a glance

  • monitoring of variable water hardness threshold values from 0.01 mmol/l to 0.18 mmol/l
  • quality-controlled regeneration release of two columns
  • continuous measurement as long as water flows
  • ecological operation because there is no use of indicators
  • self-monitoring of the device system
  • separate alarm for water hardness and service
  • measuring value output via display and via 4 to 20 mA current loop
  • manual control via display
  • data storage in electronic operations diary (flash drive)
  • easy installation and parameterization
  • networking to higher-level control centers via LAN interface with MODBUS/TCP

Ideal solution for

  • district heating
  • municipal utilities
  • hospital

Prevents

  • uneconomicalness
  • too much water consumption
  • too much use of chemicals

Advantages

  • increase in soft water throughput compared to volume controlled operation    
  • high efficiency for regeneration
  • alarm system for double water softening systems with high safety requirements for soft water quality

 

Further products

OFS GmbH

kalkablagerung effektiv verhindern / Effectively prevent scale deposits

Softcontrol Data

Visualized residual hardness control by display

Individually and clearly arranged

more: monitoring water hardness
Überwachung von Speisewasser und Dampfkesseln / control of feed water and steam boilers

HWA Analyzer

Control of feed water and steam boiler with quality controlled dosage

For more efficiency and cost savings

more: control of boiler
Überwachung von Speisewasser mit qualitativer Dosierung / monitoring of feed water with qualitative dosage

O2-Control

Monitoring of feed water with qualitative dosage

For improved efficiency of boiler operation

more: control of oxygen